Want to update an image? It’s simple! Just hover over any image on your website and click the Change Image button. You can upload your own images or choose from millions of stock photos. Any images you upload will be saved in your Media Library, making it easy to reuse them elsewhere on your website.

Menu

The floating menu on the right makes it easy to manage items within each section—you can adjust the layout, move sections up or down, or delete them. If the menu overlaps with text you're editing, you can click "hide menu" to temporarily remove it from view.

Fire Protection Services

Hero image 0
SALES OF FIRE EXTINGUISHERS image

FIRE EXTINGUISHER SALES

We offer a full range of every type and size Fire Extinguishers to suit all needs, including Red EN3 plus Polished Silver, Copper and Gold effect.

Which Extinguisher to Use
Which type and how many Extinguishers you may need will depend on the following:

⦁ size of your premises
⦁ number of employees
⦁ type of business you operate
⦁ Risk Assessment advice

Fire Classifications
Fires have different classifications as different extinguishing medium (water, carbon dioxide etc) react differently to types of fire and only the appropriate extinguisher should be used to attempt to extinguish a fire.

⦁ Class A – Freely burning materials (paper, wood etc)
⦁ Class B – Flammable liquids
⦁ Class C – Flammable gases
⦁ Class D – Flammable metals
⦁ Electrical* – Electrical equipment**
⦁ Class F – Cooking oils and fats

The Fire Extinguishers Near Me Service Engineer will advise you of your requirements and the Class of Fire you need cover for.

COMMISSIONING OF FIRE EXTINGUISHERS image

FIRE EXTINGUISHER COMMISSIONING

We’ll ensure your extinguishers adhere to BS 5306 positioning guidelines:

  • Extinguishers must be visible and readily accessible at all times.

  • Large, heavy extinguishers should hang securely on wall brackets, with the carrying handle about 1 meter from the floor.

  • Smaller extinguishers (up to 4kg) should have their carrying handle mounted at 1.5 meters from the floor.

  • If wall mounting is impractical, use suitable floor stands or consider recessed housing, cabinets, or covers, especially in schools and similar locations.

  • Maintain a maximum travel distance of 30 meters for Class A risks and 10 meters for Class B and Class F risks from the fire to reach an extinguisher.

  • Standardise operation methods, shapes, appearances, and colors for extinguishers within a building or occupancy, and indicate their location with signs.

  • Whenever possible, group portable extinguishers to create fire points with multiple exit options, extinguishers, and a means to raise the alarm.

INSTALLATION SERVICE image

FIRE EXTINGUISHER INSTALLATION SERVICE

Installation of fire extinguishers must be done correctly to ensure optimum safety and accessibility. We offer a comprehensive installation service, assessing your premises to determine the best locations for your extinguishers. We are experienced in following industry standards and regulations, ensuring that all installations meet required guidelines. We strive to make the process straightforward and hassle-free, allowing you to focus on other important aspects of your property while we take care of your fire safety needs.

12 MONTHLY FIRE EXTINGUISHERS MAINTENANCE SERVICE image

FIRE EXTINGUISHER ANNUAL MAINTENANCE SERVICE

Annually, we’ll service your extinguishers per BS 5306-3:

  • Certified Service Engineers conduct inspections, testing, and maintenance.

  • Regular checks by designated personnel ensure proper positioning and integrity.

  • Competent service technicians perform routine inspections to prevent discharges or pressure loss.

  • Per BS 5306-3, the user (company) is responsible for using a competent person for inspections, commissioning, servicing, testing, and replacing unusable extinguishers.

CALL OUT SERVICE image

CALL OUT SERVICE

We offer a call out service to refill when possible, or replace used or faulty Fire Extinguishers and parts, outside your annual service if required.

Please contact us for a FREE quote.

FIRE RISK ASSESSMENTS image

FIRE RISK ASSESSMENTS

Businesses must comply with fire safety law, specifically the Regulatory Reform (Fire Safety) Order 2005, also known as the Fire Safety Order. This law applies to England and Wales, effective from October 1, 2006.

Key points include:

Conduct a detailed fire risk assessment to identify risks and hazards in your commercial premises.

The responsible person for the premises must ensure a Fire Risk Assessment is completed by a competent person.

Record the Fire Risk Assessment if you have five or more employees or operate under a relevant license.

The responsible person must consider those at higher risk, reduce fire risks reasonably, and provide fire precautions.

Special precautions are needed for flammable/explosive materials.

Develop an emergency plan and document findings as necessary.

Maintain general fire precautions and facilities for firefighters.

Continuously review risk assessment findings.

If you lack the expertise or time, we can assist in arranging the fire risk assessment for you.

FIRE EXTINGUISHER TRAINING image

FIRE EXTINGUISHER TRAINING

We provide Training in the use of Portable Fire Extinguishers so you can feel assured that your nominated staff are trained and confident to use them in the event of a fire (if safe to do so).

In the Regulatory Reform (Fire Safety) Order 2005 (fire safety legislation) it states that the premises must be equipped with appropriate fire-fighting equipment where appropriate. With this, the person appointed responsible for fire safety must ensure that peoples training and equipment available to them are adequate.

In BS 5306-8 (Clause 4.5) it states the competent person should bring to the attention of the responsible person the legal requirement for training. Every opportunity should be taken to instruct personnel in the use of extinguishers, and to demonstrate their performance.

Extinguishers for different fire classifications will have different training requirements.

SIGNAGE image

FIRE EXTINGUISHER SIGNAGE

We supply and install all Fire Safety Signage requirements for your premises.

According to the UK Building Regulation requirements, there should be an exit sign placed on every doorway, escape window or another route which provides an exit and means of escape from a fire or other emergency situation. The signs should conform to the BS 5499 Pt 4:2000 which will meet the Building Regulations.